| USE VELAGLASS 875U FOR |
|
Flexural Strengthening |
Beams, joists, girders.
One-way and two-way slabs.
Columns.
Walls.
|
|
Shear Strengthening |
Beams, columns, walls.
Diaphragms |
|
Tensile Strengthening |
Silos, tanks, bins.
Pipes.
Chimneys |
|
Ductility Enhancement (Seismic) |
Columns, beams.
Beam-column joints |
|
Serviceability |
Crack control.
Fatigue.
Reduced deflections
|
| USE VELAGLASS 875U TO ADDRESS |
|
Increased Loads |
Increased floor live loads in buildings and warehouses (e.g. filing systems)
Increased vehicular live loads on bridges |
|
Damage and Deterioration |
Corrosion-related section loss of reinforcing steel or post-
tensioning tendons
Vehicle impact |
|
Seismic Retrofit |
Insufficient shear strength
Improper reinforcing steel details
Enhanced ductility |
|
Design/Construction Defects |
Insufficient reinforcing steel or post-tensioning tendons |
|
Other |
Cut reinforcing steel around slab openings
Restoration of historic structures
Blast upgrades
|
| Advantages |
High strength.
Lightweight, can be installed without heavy equipment.
Can be used on both, reinforced and prestressed concrete structures.
Class I flame spread classification (ASTM E84), can be used in all building types.
Durable, highly resistant to aggressive environments.
Flexible, fabric can be wrapped around structural elements.
Woven fabric is ideally suited for construction sites, fibers will not fray or separate under normal handling.
Thin, minimal aesthetic impact.
Can be applied dry or pre-impregnated with resin.
Economical, installed costs competitive with traditional alternates
|
| Limitations |
All applications of VelaGlass 875U should be evaluated and designed by a licensed engineer. All installations of VelaGlass 875U should be inspected by a qualified independent testing agency. VelaGlass 875U should not be used when the operating temperature exceeds 160 °F (70 °C) unless special precautions are taken to insulate the system.
Substrate strength for bond-critical applications should exceed 200 psi.
System is a vapor barrier. Avoid completely encapsulating concrete in areas where freeze/thaw is likely to occur
|
| Packaging |
| Available in 6, 12, 24 & 48 width x 100yds rolls
|
| Storage and Handling |
|
Store in a dry area at 40-90°F (4-32°C) away from direct sunlight, flame, or other hazards. When properly stored the product has an indefinite shelf life.
|
| Installation |
| Detailed installation procedures for VelaGlass 875U are outlined in the FiberBond Installation Manual. Installation of VelaGlass 875U should only be performed by contractors trained and certified by Edge Structural Composites.
|
| Safety |
|
Product material safety data sheets (MSDS) should be consulted during application of or when handling this product.
|
| Related Products |
The following products are typically used with VelaGlass 875U:
Veloxx LR Laminating Resin
Veloxx LVP Low Viscosity Primer
Veloxx AP Adhesive Paste/Filler
Velacoat Top Coats
Velanchor Anchors
|
|
Disclaimer/Warranty Statement
Data reported are based on testing conducted at independent testing agencies. Edge Structural Composites reserves the right to change or modify, at its discretion, and without prior notice, any of the information contained in this document.
Edge Structural Composites warrants this product to free of manufacturing defects and that it will meet the current published properties when applied per EDGEs installation procedure and tested in accordance with ASTM standards. The user determines the suitability for use of this product assumes all risk associated with its use.
|